214 Attached resistance temperature sensor with head or with cable outlet without converter or with converter
- for measuring surface temperature, such as pipes or mechanical components, surface temperature measurement is used in the caseo when
- technology cannot be interfered with
- at high medium flow speed in the pipe where the sensor protection well is abrasive
- or if the thermowell would interfere with pipe cleaning - In design with converter to convert signal of the resistance sensor to unified output signal 4 to 20 mA or digital signal (converter with HART protocol)
- In design with display to display the value of the measured value immediately
- For explosive atmosphere in areas Zone 2, Zone 1 and Zone 0 pursuant to EN 60079-10 in case of using the converter Ex ia or in case of connection to the Ex ia circuit pursuant to EN 60079-25
- For the environment, where mechanical resistance is required pursuant to EN 60068-2-6 (class AH2) and seismic capability of the electrical equipment of the safety system of the nuclear power stations pursuant to IEC 980 (MVZ level SL-2)
- The sensors with converter are rated products pursuant to the Directive 2014/30/EU of the European Parliament and the Council and EU
Appendices to download
Click on the title of an appendix to download it
- 1) Product manual (PDF 0.7 MB)