967 Stainless valve
- To close impulse piping when disconnecting a pressure sensor, to close the consumption of the orifice, output of the condensation tank etc.
- To vent the piping and in case of some designs, there is a possibility of connecting another test manometer
- As special design in the grade of purity for oxygen (O2), this armature is delivered perfectly degreased and provided with suspended blue tag (code P2S)
- As special design with cleanness of internal surfaces of grade I pursuant to TPE 10-40/1926/85 (code PC1)
- For the environment, where mechanical resistance is required pursuant to EN 60068-2-6 (class AH2) and seismic capability of the electrical equipment of the safety system of the nuclear power stations pursuant to IEC 980 (MVZ level SL-2).
- For industrial environment with high concentration of SO2 and the environment with sea climate
Appendices to download
Click on the title of an appendix to download it
- 1) Product manual 967 (PDF 0.4 MB)