991 Thermowells
- For installation of resistance or thermoelectric temperature sensors to heat sinks, i.e. sensors, which have no own heat sink, in cases
- o when there is static or dynamic pressure or aggressive environment in the place of measurement;
- o where the sensor stem does not comply with the conditions of the place of measurement;
- o when the temperature sensor needs to be replaced during the operation so that the space, in which the measurement takes place, remains closed.
- For the environment, which requires seismic resistance 1 Hz to 33 Hz and acceleration 3g, test report is issued for the following types of heat sinks
- 991105024/ZP8256, L 400 mm
- 991150xxx s L 400 mm and shorter
- 991170xxx s L 400 mm and shorter
- 991180xxx s L 400 mm and shorter - For the environment, which requires chemical resistance, it is possible to deliver heat sinks with fluoroplastic coating HALAR® (ECTFE), TEFZEL® (ETFE) and TEFLON® (PFA)
- As pressure equipment of category III pursuant to the Decree of the Government 26/2003 Coll. (Compliance assessment module B+D), EC Certificate of type test E-31-00176-03 SZÚ Brno
- Heat sinks are rated products pursuant to the Act 22/1997 Coll. and Compliance Certificate EC-991000 is issued for them.
Appendices to download
Click on the title of an appendix to download it
- 1) Product manual 991 - thermowells (PDF 0.5 MB)
- 2) EU declaration of conformity 991 (PDF 0.3 MB)